S310-24PN4X(24*10/100/1000/2.5GBASE-T ports(400W PoE+), 4*10GE SFP+ ports, built-in AC power)
| Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) | 
| Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) | 
| Chassis height [U] | 1 U | 
| Chassis material | Metal | 
| Weight without packaging [kg(lb)] | 2.92 kg (6.44 lb) | 
| Weight with packaging [kg(lb)] | 3.79 kg (8.36 lb) | 
| Typical power consumption [W] | 37.12 W | 
| Maximum power consumption [W] | •Without PoE: 44.35 W •Full PoE load: 485.91 W (PoE: 400 W) | 
| Static power consumption [W] | 27.07 W | 
| Noise at normal temperature (acoustic power) [dB(A)] | 49.3 dB(A) | 
| Noise at normal temperature (acoustic pressure) [dB(A)] | 37.3 dB(A) | 
| Number of fans modules | 2 | 
| Uplink ports | 4 x 10GE SFP+ ports | 
| Downlink ports | 24 x 10/100/1000BASE-T ports (400 W, PoE+) | 
| Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) | 
| Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). | 
| Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) | 
| Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) | 
| Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) | 
| Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) | 
| Power supply mode | AC built-in | 
| Rated input voltage [V] | •AC input: 100 V AC to 240 V AC, 50/60 Hz •High-voltage DC input: 240 V DC | 
| Input voltage range [V] | •AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz •High-voltage DC input: 190 V DC to 290 V DC | 
| Console port | RJ45 | 
| Service port surge protection [kV] | Common mode: ±7 kV | 
| Power supply surge protection [kV] | Differential mode: ±6 kV; common mode: ±6 kV | 
| Types of fans | Built-in | 
| PoE | Supported | 
| Certification | EMC certification Safety certification Manufacturing certification | 